Saving and printing information in HP Vision Field Diagnostics
You can save the information displayed in the HP Vision Field Diagnostics Survey, History and Errors
tabs to a diskette or a USB flash drive. You can not save to the hard drive. The system will automatically
create an html file that has the same appearance as the information displayed on the screen.
1.
Insert a diskette or USB flash drive if running HP Vision Field Diagnostics from CD.
2.
Click
Save
in the bottom on any of the Survey, History or Errors tabs. All three log files will be saved
regardless of from which tab the Save button was clicked.
3.
Select the drive onto which you will save the log files and click the
Save
button. Three html files
will be saved to the inserted diskette or USB flash drive.
NOTE:
Do not remove the diskette or USB key until you see a message indicating that the html
files have been written to the media.
4.
Print the desired information from the storage device used to save it.
NOTE:
To exit HP Vision Field Diagnostics, click the
Exit Diagnostics
button at the bottom of
the screen. Be sure to remove the USB flash drive or CD from the optical drive.
POST error messages
Power On Self Test (POST) is a program run at startup that initializes and runs tests on installed
hardware. An audible and/or visual message appears if the POST encounters a problem. POST checks
the following items to ensure that the workstation system is functioning properly:
NOTE:
If the power-on password is set, a key icon appears on the screen while POST is running. You
must enter the password before continuing.
Table 6-18
POST error messages
Screen message
Probable cause
Recommended action
101—Option ROM Error
System ROM checksum
Verify the correct ROM:
1.
Flash the ROM, if needed.
2.
If an expansion card was recently added, remove
it to find out if the problem remains.
3.
Clear CMOS. If the message disappears, there
might be a problem with the expansion card
4.
Replace the system board.
102—System Board Failure
DMA, timers, and so on
1.
Clear CMOS.
2.
Remove expansion boards.
3.
Replace the system board.
103—System Board Failure
DMA, timers, and so on
1.
Clear CMOS.
2.
Remove expansion boards.
3.
Replace the system board.
110—Out of Memory for
Option ROMs
Option ROM for a device was unable
to run due to memory constraints.
Run the Computer Setup (F10) Utility to enable the
ACPO/USB Buffers at Top of Memory
under the
Advanced>Power-On option.
140 Chapter 6 System diagnostics and troubleshooting