![HP StorageWorks 6000 - Virtual Library System Скачать руководство пользователя страница 317](http://html.mh-extra.com/html/hp/storageworks-6000-virtual-library-system/storageworks-6000-virtual-library-system_user-manual_165614317.webp)
Solution
Possible causes
Symptom
5.
Repeat this procedure for each
server visible to each SDLT
tape drive.
None
This is expected behavior and does
not indicate a problem.
At reboot, there are spurious critical
FC port failures reported as notific-
ation alerts, usually on every port.
Later, Info notification alerts for
each FC host port are generated,
indicating the FC ports are operat-
ing normally.
Using Command View TL on the
management station for this VLS,
go to the "License Key Summary"
tab and verify the following:
•
There is a License folder labeled
"VLS at..." with the Ethernet IP
address for this VLS system.
•
The number of license instances
in this folder ("Quantity (LTU)")
is equal to or greater than the
number of array enclosures
connected to this VLS system in
addition to the minimum config-
uration. For example, a
VLS6100–series system has a
minimum configuration of 1 ar-
ray enclosure and a
VLS6800–series has a minimum
configuration of 4 array enclos-
ures. There must be at least 1
LTU for every array enclosure
over the minimum configuration.
A VLS6800–series with 16
connected array enclosure
needs 12 correctly installed LTU
license keys.
•
Verify the correct VLS system
Identifier was used and entered
correctly when the license key
was created. If licenses that
were installed for this system
show up under the "Un-man-
aged Licenses" license folder,
then Command View TL can not
match the Identifier for that li-
cence to any known library
device.
Whenever the VLS detects more
array enclosures than there are
correctly installed licenses, the VLS
system will disable ALL array stor-
age and report 0 GB of Total Us-
able Capacity.
The Identity tab of Command View
VLS reports Total Usable Capacity
of 0 GB, even though there are
working disk arrays available to
the VLS system.
If a blank drive is installed in drive
bay 0, the system will not boot. To
remedy this, switch the drive loc-
ated in bay 0 with the drive located
in bay 1.
A blank drive was installed in drive
bay 0.
After replacing drive 0 in a node,
the system will not boot.
HP StorageWorks
317
Содержание StorageWorks 6000 - Virtual Library System
Страница 26: ...Introduction 26 ...
Страница 70: ...Storage Configuration 70 ...
Страница 116: ...Automigration Replication 116 ...
Страница 132: ...Operation 132 ...
Страница 140: ...User Interfaces 140 ...
Страница 178: ...Management 178 ...
Страница 256: ...Component Identification 256 ...
Страница 300: ...Component Replacement 300 ...
Страница 310: ...Support and Other Resources 310 ...
Страница 326: ...Specifications 326 ...
Страница 332: ...French Laser Notice German Laser Notice Italian Laser Notice Regulatory Compliance Notices 332 ...
Страница 333: ...Japanese Laser Notice Spanish Laser Notice Recycling Notices English Notice HP StorageWorks 333 ...
Страница 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Страница 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Страница 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Страница 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Страница 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Страница 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Страница 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Страница 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Страница 348: ...Glossary 348 ...
Страница 358: ...358 ...