![HP StorageWorks 6000 - Virtual Library System Скачать руководство пользователя страница 303](http://html.mh-extra.com/html/hp/storageworks-6000-virtual-library-system/storageworks-6000-virtual-library-system_user-manual_165614303.webp)
1.
Set the network settings so you can open a Command View VLS session. See
Setting the Network
Settings
.
2.
Rebuild the virtual library and virtual drive configurations and re-enter your other configuration
settings, such as the notification alert settings. See
Configuration
,
Management
, and
Monitoring
.
NOTE:
If the node system board was ever changed and the virtual library configuration and network settings
were not saved to a configuration file, the persistent VLS serial number and Fibre Channel port
WWPNs are lost and cannot be recovered. The VLS firmware will automatically generate a new VLS
serial number and new Fibre Channel port WWPNs based on the node system board's MAC address.
If this occurs, any capacity licenses installed on the VLS will no longer work, as they only work with
the VLS serial number for which they were issued. You can obtain new capacity licenses from HP
technical support using the new VLS serial number. You will also need to reconfigure your SAN to
reflect the new Fibre Channel port WWPNs.
Re-installing the VLS Licenses
If one or more capacity bundles (or existing disk arrays), deduplication licenses, and/or replication
licenses were added to the VLS, you must re-install the VLS licenses.
To re-install the VLS licenses from Command View VLS (HP recommended method):
1.
Locate the emails containing the license keys.
Your VLS license keys were emailed to you when you originally requested them. If you no longer
have these emails, contact HP technical support to obtain new license keys.
2.
Log into Command View VLS.
3.
Follow the
Installing Additional Licenses
procedure beginning with
Step 9
.
To re-install the VLS licenses from Command View TL:
1.
Locate the emails containing the license keys.
Your VLS license keys were emailed to you when you originally requested them. If you no longer
have these emails, contact HP technical support to obtain new license keys.
2.
Log into Command View TL.
3.
Delete the VLS licenses in Command View TL.
4.
Ignore the message saying to reboot the device.
5.
Re-install the VLS license keys. See the
HP OpenView Command View for TL User Guide
.
Warm Failover
After any configuration or license change, the VLS automatically saves (within one hour) the updated
configuration and licenses to a hidden virtual cartridge stored on the back-end disk arrays. When
you replace the node or node hard drives, the VLS uses this information to automatically restore the
system to a configuration identical to what it had before. This automated process eliminates the need
to manually restore the configuration.
HP StorageWorks
303
Содержание StorageWorks 6000 - Virtual Library System
Страница 26: ...Introduction 26 ...
Страница 70: ...Storage Configuration 70 ...
Страница 116: ...Automigration Replication 116 ...
Страница 132: ...Operation 132 ...
Страница 140: ...User Interfaces 140 ...
Страница 178: ...Management 178 ...
Страница 256: ...Component Identification 256 ...
Страница 300: ...Component Replacement 300 ...
Страница 310: ...Support and Other Resources 310 ...
Страница 326: ...Specifications 326 ...
Страница 332: ...French Laser Notice German Laser Notice Italian Laser Notice Regulatory Compliance Notices 332 ...
Страница 333: ...Japanese Laser Notice Spanish Laser Notice Recycling Notices English Notice HP StorageWorks 333 ...
Страница 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Страница 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Страница 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Страница 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Страница 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Страница 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Страница 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Страница 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Страница 348: ...Glossary 348 ...
Страница 358: ...358 ...