![HP StorageWorks 6000 - Virtual Library System Скачать руководство пользователя страница 152](http://html.mh-extra.com/html/hp/storageworks-6000-virtual-library-system/storageworks-6000-virtual-library-system_user-manual_165614152.webp)
To get around the maximum LUNs per device restriction, you can either:
•
Increase the maximum LUNs per device setting for the operating system. See
“
Troubleshooting
” on page 311 for more information.
•
Enable LUN mapping on the VLS to restrict the number of virtual devices the host's operating system
sees on the VLS Fibre Channel host ports. See “
LUN Mapping (v3.x)
” on page 153 or
“
LUN Mapping (v2.x)
” on page 159 for instructions.
LUN Masking
The method of LUN masking differs between VLS firmware versions 3.x and 2.x.
LUN Masking (v3.x)
LUN masking restricts a host's access to the virtual devices (virtual libraries and/or tape drives) on
the VLS. You should use it when there are more virtual device LUNs mapped to an Fibre Channel host
port than the operating system LUN restrictions support. You can limit the LUNs the host's operating
system can see on the port, so that only the virtual devices the host needs to see are visible.
For example, if a host's operating system is configured to only see up to eight LUNs per Fibre Channel
host port, the host will not be able to see the virtual devices numbered LUN8, LUN9, and up. Suppose
that you need the host to see LUN0 through LUN5, LUN8, and LUN9. You can enable LUN mapping,
thereby hiding all of the LUNs from the host. Then you can map LUN0 through LUN5, LUN8, and
LUN9 to the host. The VLS will automatically renumber the mapped LUNs so that LUNs 8 and 9
become LUNs 6 and 7 and they are now within the eight the host can see. See
“
LUN Mapping (v3.x)
” on page 153.
In the VLS, LUN masking occurs automatically for all hosts when you enable LUN mapping using the
global enable/disable LUN mapping setting. See “
Setting the Default LUN Mapping
” on page 153.
LUN Masking (v2.x)
By default all hosts on the SAN can access all the virtual libraries on the VLS. You can restrict a host's
access to the virtual libraries and/or tape drives (virtual devices) on the VLS by performing LUN
masking.
LUN masking should also be used when there are more virtual devices (LUNs) port mapped to a FC
host port than the operating system LUN restrictions support. This prevents the host's operating system
from seeing the virtual devices it needs to see on the port. For example, if a host's operating system
is configured to only see up to eight LUNs per FC host port, the host will not be able to see the virtual
devices numbered LUN8, LUN9, ..., and up. LUN masking limits the virtual devices (LUNs) the host's
operating system can see on the port, so that only the virtual devices the host needs to see are visible.
To perform LUN masking:
1.
Open a Command View VLS session and log in as the administrator. See
“
Opening a Command View VLS Session from a Web Browser
” on page 135.
2.
Click the
System
tab.
3.
Select
Chassis
in the navigation tree.
Configuration
152
Содержание StorageWorks 6000 - Virtual Library System
Страница 26: ...Introduction 26 ...
Страница 70: ...Storage Configuration 70 ...
Страница 116: ...Automigration Replication 116 ...
Страница 132: ...Operation 132 ...
Страница 140: ...User Interfaces 140 ...
Страница 178: ...Management 178 ...
Страница 256: ...Component Identification 256 ...
Страница 300: ...Component Replacement 300 ...
Страница 310: ...Support and Other Resources 310 ...
Страница 326: ...Specifications 326 ...
Страница 332: ...French Laser Notice German Laser Notice Italian Laser Notice Regulatory Compliance Notices 332 ...
Страница 333: ...Japanese Laser Notice Spanish Laser Notice Recycling Notices English Notice HP StorageWorks 333 ...
Страница 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Страница 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Страница 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Страница 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Страница 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Страница 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Страница 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Страница 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Страница 348: ...Glossary 348 ...
Страница 358: ...358 ...