Log Monitor Summary
The
Log Monitor Summary
displays decompression error details. You may sort the table by selecting
a column header. You may delete errors by selecting the rows and then selecting
Delete Selected
.
When enclosure and/or IP address calculations are pending, select
Refresh
to refresh the information
in the table.
Refresh Array Info
updates cached array information on the server. Use this if you make
architectural changes such as adding arrays to the VLS.
The log monitor table displays:
•
Time — the date and time the decompression error was logged in the system log.
•
SDev Number — the Set Device number logged in the decompression error.
•
LBA — Logical Block Address, representing the hex value of the logical location of the error in the
RAID set.
•
Offset — the distance in Hex from the beginning of the LBA, to the occurrence of the decompression
error.
•
Length — the length in Hex of the decompression error.
Log File Fields
The log file is a comma-separated values (CSV) file-format. The data fields are separated by commas
or columns depending on the program used to view the file.
Test summaries are logged at the beginning and end of a test. The data fields are in order as follows:
•
Test_summary — indicates that this row of data is the test summary information
•
Test summary ID
•
Date of the test
•
Test type — Background or Read-only
•
Storage pools — All or the number of the storage pool tested
•
Test start time
•
Test end time
•
Current job count
•
Total job count
•
Total amount of data written during the test
•
Total amount of data read during the test
•
Total number of successful jobs
•
Total number of failed jobs
•
Status of the test
Decompression errors will be logged once per occurrence. The data fields are in order as follows.
See “
Log Monitor Summary
” on page 199 for descriptions not defined here:
•
Decompression_error — indicates that this row of data is the decompression information.
•
Decompression error ID
•
Time the error occurred
•
sDev Number
•
LBA
•
Offset
•
Length
HP StorageWorks
199
Содержание StorageWorks 6000 - Virtual Library System
Страница 26: ...Introduction 26 ...
Страница 70: ...Storage Configuration 70 ...
Страница 116: ...Automigration Replication 116 ...
Страница 132: ...Operation 132 ...
Страница 140: ...User Interfaces 140 ...
Страница 178: ...Management 178 ...
Страница 256: ...Component Identification 256 ...
Страница 300: ...Component Replacement 300 ...
Страница 310: ...Support and Other Resources 310 ...
Страница 326: ...Specifications 326 ...
Страница 332: ...French Laser Notice German Laser Notice Italian Laser Notice Regulatory Compliance Notices 332 ...
Страница 333: ...Japanese Laser Notice Spanish Laser Notice Recycling Notices English Notice HP StorageWorks 333 ...
Страница 334: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 334 ...
Страница 335: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 335 ...
Страница 336: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 336 ...
Страница 337: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 337 ...
Страница 339: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 339 ...
Страница 340: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 340 ...
Страница 341: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 341 ...
Страница 342: ...Spanish Battery Notice Regulatory Compliance Notices 342 ...
Страница 348: ...Glossary 348 ...
Страница 358: ...358 ...