Slot:
In OSM Service Connection displays:
◦
–
1 represents the ServerNet PCI adapter card.
The ServerNet PCI card is installed in the third PCI slot in the rx2800 i4.
–
3 and 4 represent the power supplies on the blade element.
OSM slot 3 represents power supply 1; OSM slot 4 represents power supply 2.
–
32 through 37 represent the fans on the blade element.
OSM slot 32 represents fan 1, OSM slot 33 represents fan 2, and so on.
◦
In the OSM Low-Level Link, 1 relates to the location of the processor. Because each
blade element contains only one processor, it is always located in slot 1.
Example: slot 1 = any processor in any blade element.
•
Port: X and Y relate to the two ServerNet fabric ports in slot 1.
These tables show the default numbering for the blade elements of a NS2300 system when
blade elements are powered on and functioning:
NOTE:
In OSM, if a blade element is not present or is powered off, processors might be
renumbered. For example, if processor 2 has been removed, processor 3 becomes processor
2 in OSM displays.
GMS Numbering Displayed in the OSM Service Connection:
Port (Slot 2 only)
Slot
Module
Group*
Processor
ID
Processor
Blade
Element
X
1, PCI adapter card.
(physical PCI slot 1)
100
1
400
0
Y
101
1
401
1
3 - 4, power supplies.
(physical power supplies 1
and 2)
102
1
402
2
103
1
403
3
32 - 37, fans (physical fans
1 through 6)
*In OSM, the term Blade Complex is used for the group.
GMS Numbering Displayed in the OSM Low-Level Link:
Slot
Module
Group*
Processor ID
1
100
400
0
1
101
400
1
1
102
400
2
1
103
400
3
*In OSM, the term Blade Complex is used for the group.
22
Identifying NS2300 System Components
Содержание Integrity NonStop i NS2300
Страница 5: ...Ukraine RoHS material content declaration 79 Index 80 Contents 5 ...
Страница 9: ...Figure 1 Example NS2300 System Configuration 42U 9 ...
Страница 31: ...Figure 3 Intelligent PDU Connections Without UPS Power Distribution for NS2300 Systems 31 ...
Страница 33: ...Figure 5 Intelligent PDU Connections With Three Phase UPS Power Distribution for NS2300 Systems 33 ...
Страница 35: ...Figure 7 Modular PDU Connections With Single Phase UPS Power Distribution for NS2300 Systems 35 ...
Страница 36: ...Figure 8 Modular PDU Connections With Three Phase UPS 36 System Installation Specifications for NS2300 Systems ...
Страница 38: ...Figure 9 Example of Bottom AC Power Feed Without UPS 38 System Installation Specifications for NS2300 Systems ...
Страница 39: ...Figure 10 Example of Top AC Power Feed Without UPS Power Distribution for NS2300 Systems 39 ...
Страница 41: ...Figure 12 Example of Bottom AC Power Feed With Single Phase UPS Power Distribution for NS2300 Systems 41 ...