On NS2300 systems, locations of the modular components are identified by:
•
Physical location:
Rack number
◦
◦
Rack offset
•
Logical location:
◦
Group, module, and slot (GMS) notation as defined by their position on the ServerNet
rather than the physical location
OSM uses GMS notation in many places, including the Tree view and Attributes window, and it
uses rack and offset information to create displays of the server and its components. For example,
in the Tree view, OSM displays the location of a power supply in a VIO enclosure in group 100,
module 2, slot 15 in this form:
Power Supply (100.2.15)
Rack and Offset Physical Location
Rack name and rack offset identify the physical location of components in a NS2300 system.
The rack name is located on an external label affixed to the rack, which includes the system
name plus a 2-digit rack number.
Rack offset is labeled on the rails in each side of the rack. These rails are measured vertically
in units called
U
, with one U measuring 1.75 inches (44 millimeters). The rack is 36U with 1U
located at the bottom and 36U at the top or 42U with 1U located at the bottom and 42U at the
top. The rack offset is the lowest number on the rack that the component occupies.
Blade Element Group-Module-Slot Numbering
•
Group:
In OSM Service Connection displays, 400 through 403 relates to blade complexes 0
through 4. Each blade complex includes a blade element and its associated processor.
Example: group 403 = blade complex 3
◦
◦
In the OSM Low-Level Link, 400 relates to all blade complexes.
Example: group 400 = any blade complex
•
Module:
In OSM Service Connection displays, a module represents either the blade element or
the processor:
◦
–
In a NS2300 system, all blade elements are module 1.
Example: module 1 = any blade element
–
100-103 relates to processors 0-3
Example: module 102 = processor 2
◦
In the OSM Low-Level Link, 100 through 103 relates to processors 0 through 3.
Example: module 103 = processor 3
Component Location and Identification in a NS2300 System
21
Содержание Integrity NonStop i NS2300
Страница 5: ...Ukraine RoHS material content declaration 79 Index 80 Contents 5 ...
Страница 9: ...Figure 1 Example NS2300 System Configuration 42U 9 ...
Страница 31: ...Figure 3 Intelligent PDU Connections Without UPS Power Distribution for NS2300 Systems 31 ...
Страница 33: ...Figure 5 Intelligent PDU Connections With Three Phase UPS Power Distribution for NS2300 Systems 33 ...
Страница 35: ...Figure 7 Modular PDU Connections With Single Phase UPS Power Distribution for NS2300 Systems 35 ...
Страница 36: ...Figure 8 Modular PDU Connections With Three Phase UPS 36 System Installation Specifications for NS2300 Systems ...
Страница 38: ...Figure 9 Example of Bottom AC Power Feed Without UPS 38 System Installation Specifications for NS2300 Systems ...
Страница 39: ...Figure 10 Example of Top AC Power Feed Without UPS Power Distribution for NS2300 Systems 39 ...
Страница 41: ...Figure 12 Example of Bottom AC Power Feed With Single Phase UPS Power Distribution for NS2300 Systems 41 ...