Table 36 Warning event codes
(continued)
Details and Solution
Description
Event code
drive has been installed. Use only HP-approved
support to insure that the correct tape drives are
used.
Verify that a supported magazine for that slot is
inserted. If the magazine is in the lower left
SCSI: incompatible magazine, magazine not
accessible
49
position, verify that the type of magazine is
consistent with the mailslot configuration.
•
Retry the operation.
Source not ready
4A
•
Retry the operation.
Destination not ready
4B
The application software made an illegal request.
Reservation failed
4C
Retry the operation.
Library controller busy
4D
Invalid robotic request
4E
Robotic not initialized
4F
Incompatible medium
51
•
Verify that the drives are installed correctly.
•
Verify that the cartridge and tape drive
generation are compatible. See
.
•
Verify that the tape is correct for the operation
initiated.
Remove a cartridge from the device to make a slot
available for the move operation.
All slots full; no movement possible
52
Load tapes in the four top-level corner slots. See
.
Wellness test: invalid test setup
53
Invalid license key
55
•
Verify that the correct license key was entered.
•
Verify that the
Caps Lock
key is not depressed.
The key is case sensitive.
Ensure that the key server token containing the key
used to encrypt the tape is installed in the USB
port.
No decryption key available on token
56
Use the RMI to enter the PIN for the key server
token that is installed in the USB port.
Key server token PIN required
57
NOTE:
The PIN is required every time a token
is installed in the USB port and every time the
Autoloader is powered on.
Parity error
58
•
Retry the operation.
Error log overflow
59
•
If the problem continues, contact HP customer
support.
Disable encryption before downgrading firmware.
Unable to downgrade firmware while encryption
enabled.
5A
Invalid cartridge. LTO3 media is not supported
with encryption enabled.
5B
•
Verify that the tape cartridge is supported.
•
Update the tape drive firmware to the latest
version to use LTO3 media.
Change the network settings to IPv4 before
downgrading firmware.
IPv6 will not be supported after downgrading
firmware.
5C
124
Troubleshooting
Содержание BL536A
Страница 149: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 149 ...
Страница 151: ...Danish notice Dutch notice Estonian notice Finnish notice French notice Recycling notices 151 ...
Страница 152: ...German notice Greek notice Hungarian notice Italian notice Latvian notice 152 Regulatory compliance and safety ...
Страница 153: ...Lithuanian notice Polish notice Portuguese notice Romanian notice Slovak notice Recycling notices 153 ...
Страница 155: ...French battery notice German battery notice Battery replacement notices 155 ...
Страница 156: ...Italian battery notice Japanese battery notice 156 Regulatory compliance and safety ...