For complete testing, enable the mailslot and ensure that each corner slot contains a tape cartridge.
The corner slot positions are M1, 3, 4, and 7 when the mailslot is enabled
IMPORTANT:
The Autoloader will remove any tape cartridge from the tape drive and go offline
when running the Wellness test. Verify that any applications using the device have completed
before starting the wellness test.
You can have the device run up to 10 cycles of the wellness test.
The wellness test requires operator interaction and can only be run from the OCP. During the
wellness test:
1.
The operator starts the wellness test from the OCP. The administrator password is required.
2.
The device performs a self test and verifies that it can communicate with the tape drive.
3.
The Autoloader returns the tape cartridge in the tape drive to its home slot, if necessary. If the
home slot is not known, the Autoloader will move the cartridge to the mailslot and prompt the
operator to remove it.
4.
The device prompts the operator to enter the number of cycles to run the test.
5.
The device opens the mailslot and prompts the operator to insert a scratch cartridge.
6.
The operator inserts a scratch cartridge into the mailslot. If the mailslot is disabled or the
operator closes the mailslot without inserting a cartridge into the mailslot, the device will
perform a shortened version of the wellness test, skipping step 7.
7.
The device loads the scratch cartridge into the tape drive, unloads the scratch cartridge from
the tape drive, and returns the scratch cartridge to the mailslot.
8.
The device moves the tape cartridge from the four top-row corner slots to the tape drive load
point and then returns the tape cartridge to its slot. If one of the top-row corner slot positions
does not contain a tape cartridge, the device will skip that location. If none of the top-row
corner slots contain a tape cartridge, the device displays an error message.
9.
If additional cycles remain to be run, the test will return to step 7 if there is a tape cartridge
in the mailslot or step 8 if there is not a cartridge in the mailslot.
10. At the conclusion of the test, the device pops open the mailslot and waits for the operator to
remove the scratch tape.
11. The device displays the test completion status, including any recoveries or errors that may
have occurred.
Error codes
If an error occurs during operation, the device stops the current operation and displays an error
code on the LCD screen. Unless otherwise noted in
, record the
error code or error message from the LCD screen, and then try to resolve the error by cycling power
to the device and retrying the operation.
To check the overall operation of the device, run the wellness test from the RMI or OCP. The wellness
test exercises all robotic movements and checks the status of the electrical components and
communication. To run the wellness test from the RMI, see
Performing general diagnostics (page 60)
.
To run the wellness test from the OCP, see
Running the wellness test (Support > Run Wellness Test)
.
Error codes 105
Содержание BL536A
Страница 149: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 149 ...
Страница 151: ...Danish notice Dutch notice Estonian notice Finnish notice French notice Recycling notices 151 ...
Страница 152: ...German notice Greek notice Hungarian notice Italian notice Latvian notice 152 Regulatory compliance and safety ...
Страница 153: ...Lithuanian notice Polish notice Portuguese notice Romanian notice Slovak notice Recycling notices 153 ...
Страница 155: ...French battery notice German battery notice Battery replacement notices 155 ...
Страница 156: ...Italian battery notice Japanese battery notice 156 Regulatory compliance and safety ...