Test Descriptions
Composite Triple Beat
Test Description
More about the
MORE INFO
Screen
The
MORE INFO
screen is intended to explain how the
result is calculated and to assist
you in making sure this result reflects the actual beat level on the signal being measured. To assist
you in adjusting the input level, the
MORE INFO
screen has several messages instructing you to
raise or lower the input level and try the test again. In addition, when conditions warrant it, other
message prompts suggesting preselection or other actions can appear on this screen. These messages
only occur when the analyzer signal-near-noise correction is correcting more than 3 The messages
are as follows:
Raise Input Levelxto y
This message appears when there is a need to raise the cable noise level and more input power
can be tolerated without overload.
Input Levelxtoy
This message may appear as an alternative to raising the input level. It appears when it may be
possible to reduce the input power a small amount but just enough to cause the analyzer to switch
its internal 10 attenuator down by 1 step. This has the effect of raising the input level by
10 less the number of the input level was reduced by. Try this when raising the level is
inconvenient or impossible for some reason. Alternatively, when this message appears it signals that
it may be possible to not change the level at all, but to
the test and reduce the attenuator
manually using the
keys on the 2nd C/N menu.
Preselect Input Signal:
This message appears when there is no longer any headroom to raise the level before overload
occurs, but there is still need to raise the cable noise level and there is significant channel loading
present.
The messages above are the analyzer best guess as to what to do given the conditions it can
determine. They are not foolproof and are intended to be taken as suggestions only, not concrete rules
for what to do.
8-22
Содержание 8591C
Страница 2: ...I User s Guide HP 8591C Cable TV Analyzer Cable TV Measurements ...
Страница 22: ...I Glossary Index Contents 7 ...
Страница 27: ...Contents ...
Страница 28: ...I 1 Getting Started ...
Страница 33: ......
Страница 43: ...I Getting Started ...
Страница 44: ...I 2 Channel Measurements ...
Страница 107: ...I Channel Measurements Making Channel Measurements ...
Страница 108: ...3 System Measurements ...
Страница 147: ...System Measurements Deleting Individual Files from a RAM Card ...
Страница 148: ...I 4 If You Have a Problem ...
Страница 165: ...I If You Have a Problem How to Contact Hewlett Packard ...
Страница 166: ...I 5 Channel Measurements Menu Map and Softkey Descriptions ...
Страница 193: ...I Channel Measurements Menu Map and Softkey Descriptions ...
Страница 194: ...6 System Measurements Menu Map and Softkey Descriptions ...
Страница 231: ...System Measurements Menu Map and Softkey Descriptions System Measurements Softkey Function Descriptions ...
Страница 232: ...I 7 TV Receiver Setup and AUX CTRL Menu Maps and Softkey Descriptions ...
Страница 233: ......
Страница 253: ...I TV Receiver Setup and AUX CTRL Menu Maps and Softkey Descriptions Softkey Descriptions ...
Страница 254: ...I 8 Test Descriptions ...
Страница 301: ...Test Descriptions View Co Channel Test Description ...
Страница 302: ...9 Specifications and Test Aids ...
Страница 325: ...Specifications and Test Aids Channel Survey Map ...
Страница 326: ...Specifications and Test Aids Channel Survey Map I Channel Line Number Number Odd ...
Страница 327: ...Specifications and Test Aids Channel Survey Map Even 1 I I I I ...
Страница 328: ...Specifications and Test Aids Channel Survey Map ...
Страница 329: ...I Specifications and Test Aids Channel Survey Map 9 2 8 ...
Страница 330: ...Specifications and Test Aids Channel Survey Map ...
Страница 331: ...Specifications and Test Aids Channel Survey Map ...
Страница 332: ...I Specifications and Test Aids Channel Survey Map ...
Страница 333: ...Specifications and Test Aids ...
Страница 334: ...Glossary ...
Страница 353: ...Index ...