Server agents 113
Event Title: Rack Power Subsystem Not Redundant
Log Message: The rack power subsystem is no longer in a redundant state.
SNMP Trap: cpqRackPowerSubsystemNotRedundant - 22018 in CPQRACK.MIB
Symptom: The rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible to return the system to a
redundant state.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid
•
cpqRackPowerEnclosureName
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power subsystem in enclosure
[cpqRackPowerEnclosureName] in rack [cpqRackName] is no longer redundant.”
NT Event ID: 1161 (Hex)0x84350489 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Input Voltage Problem
Log Message: The rack power supply detected an input line voltage problem.
SNMP Trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB
Symptom: The rack power supply detected an input line voltage problem.
User Action: Check the power input for the power supply or replace any failed power supplies as
soon as possible.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid
•
cpqRackPowerSupplyEnclosureName
•
cpqRackPowerSupplyPosition
•
cpqRackPowerSupplyFWRev
•
cpqRackPowerSupplyInputLineStatus
•
cpqRackPowerSupplySparePartNumber
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The rack power supply detected an input line voltage problem in
power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack
[cpqRackName].”
NT Event ID: 1162 (Hex)0x8435048a (cpqsvmsg.dll)