Server agents 119
•
cpqRackServerBladePosition
•
cpqRackServerBladeSparePartNumber
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] inserted into position
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1172 (Hex)0x84350494 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Load Balanced
Log Message: The power subsystem is out of balance for this power enclosure.
SNMP Trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB
Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this power
enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies. Add additional power supplies if needed.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid
•
cpqRackCommonEnclosureName
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureSparePartNumber
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem not load balanced in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem DC Power Problem
Log Message: There is a power subsystem DC power problem for this enclosure.
SNMP Trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB
Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for
this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName