Storage agents 60
•
cpqTapeLibraryFwRev
•
cpqTapeLibrarySerialNumber
•
cpqTapeLibraryState
Supporting SNMP Trap Description: “Status is now [cpqTapeLibraryState].”
NT Event ID: 1192 (Hex)0x843504a8 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Drive Status Change.
Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4 has a new status of %2.
SNMP Trap: cpqTape5PhyDrvStatusChange - 5019 in CPQSCSI.MIB
Symptom: Tape Drive Status Change. The Storage Agent has detected a change in the status of a
tape drive. The current physical drive status is indicated in the cpqTapePhyDrvStatus variable.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqTapePhyDrvCntlrIndex
•
cpqTapePhyDrvBusIndex
•
cpqTapePhyDrvScsiIdIndex
•
cpqTapePhyDrvLunIndex
•
cpqTapePhyDrvName
•
cpqTapePhyDrvFwRev
•
cpqTapePhyDrvSerialNumber
•
cpqTapePhyDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvStatus].”
NT Event ID: 1193 (Hex)0x843504a9 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Tape Drive Status Change.
Log Message: The tape drive at location “%4”, has a new status of %7.
SNMP Trap: cpqExtTapeDriveStatusChange - 16023 in CPQFCA.MIB
Symptom: External Tape Drive Status Change. This trap indicates that the agent has detected a
change in the status of an External Tape Drive. The variable cpqFcTapeDriveStatus indicates the
current tape status.
User Action: If the tape is failed or is offline, check the tape and all connections.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqFcTapeDriveCntlrIndex
•
cpqFcTapeDriveScsiBus
•
cpqFcTapeDriveScsiTarget
•
cpqFcTapeDriveScsiLun