NIC agents 135
Log Message: The NIC SNMP Management Agent has determined the Insight Agent Management
service is running.
Event identifier: cpqnimsg.dll - 1040 (Hex)0x44350410 (Service Event)
Log Severity: Information (1)
Log Message: The agent could not deliver trap %1. The agent was unable to use Asynchronous
Management to deliver a trap. This can be caused by a failure in the Remote Access Service or by a
missing or invalid configuration. Use the Insight Agent control panel to verify the Asynchronous
Management configuration settings. Use the Network control panel to verify the Remote Access
configuration. If this error persists, reinstalling the Insight Agents or the Remote Access Service may
correct this error. For more information, see the Insight Asynchronous Management documentation.
NT Event ID: 1282 (Hex)0x44350502 (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Redundancy has been increased by the NIC in slot %1, port %2. Number of functional
NICs in the team: %3.
SNMP Trap: cpqNicRedundancyIncreased - 18003 in CPQNIC.MIB
Symptom: This trap is sent any time a previously failed physical adapter in a connected logical
adapter group returns to the OK condition. This trap is not sent when a logical adapter group has
connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead.
This can be caused by replacing a faulty cable or by connecting a cable that was disconnected.
User Action: None required.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqNicIfPhysAdapterSlot
•
cpqNicIfPhysAdapterPort
•
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: “Redundancy increased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1283 (Hex)0xc4350503 (cpqnimsg.dll)
Log Severity: Error (3)
Log Message: Redundancy has been reduced by the NIC in slot %1, port %2. Number of functional
NICs in the team: %3.
SNMP Trap: cpqNicRedundancyReduced - 18004 in CPQNIC.MIB
Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the
Failed condition, but at least one physical adapter remains in the OK condition. This can be caused
by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter,
Hub, or Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found,
the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
•
sysName