Storage agents 47
•
cpqHoTrapFlags
•
cpqSsChassisName
•
cpqSsChassisTime
•
cpqSsPowerSupplyBay
•
cpqSsPowerSupplyUpsStatus
Supporting SNMP Trap Description: “Storage system power supply UPS status changed to
[cpqSsPowerSupplyUpsStatus].”
NT Event ID: 1155 (Hex)0x84350483 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Sensor Status Change.
Log Message: Storage system “%4” temperature sensor at location %5 has a new status of %6 and a
current temperature value of %7 celsius.
SNMP Trap: cpqSsExTempSensorStatusChange - 8019 in CPQSTSYS.MIB
Symptom: Storage system temperature sensor status change. The agent has detected a change in the
status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the
current status.
User Action: If the temperature status is degraded or failed, shut down the storage system as soon as
possible. Be sure that the storage system environment is being cooled properly and that no
components are overheated.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsChassisName
•
cpqSsChassisTime
•
cpqSsTempSensorLocation
•
cpqSsTempSensorStatus
•
cpqSsTempSensorCurrentValue
Supporting SNMP Trap Description: “Storage system temperature sensor status changed to
[cpqSsTempSensorStatus].”
NT Event ID: 1156 (Hex)0x84350484 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Library Failed.
Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller
in slot %4 has encountered an error.
SNMP Trap: cpqTape3LibraryFailed - 5010 in CPQSCSI.MIB
Symptom: Tape Library Error. The Insight Agent has detected that an autoloader unit has encountered
an error.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags