Server agents 98
•
cpqHeFltTolPowerSupplySerialNumber
•
cpqHeFltTolPowerSupplyAutoRev
•
cpqHeFltTolPowerSupplyFirmwareRev
•
cpqHeFltTolPowerSupplySparePartNum
•
cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply is Failed on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status
[cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num
[cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1126 (Hex)0x84350466 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Fault Tolerant Power Supply Sub-system has lost redundancy. Restore power or
replace any failed or missing power supplies.
SNMP Trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB
Symptom: The Fault Tolerant Power Supplies have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqHeFltTolPowerSupplyChassis
Supporting SNMP Trap Description: “The Power Supplies are no longer redundant on Chassis
[cpqHeFltTolPowerSupplyChassis].”
NT Event ID: 1127 (Hex)0x44350467 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Fault Tolerant Power Supply Inserted. A hot-plug fault tolerant power supply has been
inserted into the system.
SNMP Trap: cpqHe3FltTolPowerSupplyInserted - 6033 in CPQHLTH.MIB
Symptom: A Fault Tolerant Power Supply has been inserted into the specified chassis and bay
location.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqHeFltTolPowerSupplyChassis
•
cpqHeFltTolPowerSupplyBay
Supporting SNMP Trap Description: “The Power Supply Inserted on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”
NT Event ID: 1128 (Hex)0x84350468 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Fault Tolerant Power Supply Removed. A hot-plug fault tolerant power supply has been
removed from the system.
SNMP Trap: cpqHe3FltTolPowerSupplyRemoved - 6034 in CPQHLTH.MIB