Storage agents 44
•
cpqSsChassisName
•
cpqSsChassisTime
•
cpqFcaAccelBoxIoSlot
•
cpqFcaAccelStatus
•
cpqFcaCntlrModel
•
cpqFcaAccelSerialNumber
•
cpqFcaAccelTotalMemory
•
cpqFcaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqFcaAccelStatus].”
NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array
“%4” is reporting that it contains bad cached data.
SNMP Trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB
Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected
an Array Accelerator Cache Board that has lost battery power. If data was being stored in the
accelerator memory when the system lost power, that data has been lost.
User Action: Verify that no data has been lost.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsChassisName
•
cpqSsChassisTime
•
cpqFcaAccelBoxIoSlot
•
cpqFcaCntlrModel
•
cpqFcaAccelSerialNumber
•
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”
NT Event ID: 1150 (Hex)0xc435047e (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Battery Failed.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array
“%4” is reporting a battery failure.
SNMP Trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB
Symptom: External Array Accelerator Board Battery failed. This trap indicates that the agent has
detected a battery failure associated with the Array Accelerator Cache Board.
User Action: Replace the Accelerator Cache Board.
Supporting SNMP Trap Data:
•
sysName