Server agents 120
•
cpqRackUid
•
cpqRackCommonEnclosureName
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureSparePartNumber
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem DC power problem in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1174 (Hex)0x84350496 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Facility AC Power Problem
Log Message: The AC facility input power has been exceeded for this power enclosure.
SNMP Trap: cpqRackPowerChassisAcFacilityPowerExceeded - 22032 in CPQRACK.MIB
Symptom: Power subsystem AC facility input power exceeded for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid
•
cpqRackCommonEnclosureName
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureSparePartNumber
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem AC facility input power exceeded in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1175 (Hex)0x84350497 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Unknown Power Consumption
Log Message: There is an unknown power consumer drawing power.
SNMP Trap: cpqRackPowerUnknownPowerConsumption - 22033 in CPQRACK.MIB
Symptom: Unknown power consumption. There is an unknown power consumer drawing power.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid