Storage agents 38
Supporting SNMP Trap Description: “Storage System will be shut down.”
NT Event ID: 1077 (Hex)0x84350435 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Degraded.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4
system has a temperature outside the normal operating range.
SNMP Trap: cpqSs3TempDegraded - 8010 in CPQSTSYS.MIB
Symptom: Storage System temperature degraded. The agent has detected a temperature status that
has been set to degraded. The storage system's temperature is outside of the normal operating range.
User Action: Shut down the storage system as soon as possible. Be sure that the storage system
environment is being cooled properly and that no components are overheated.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsBoxTempStatus
Supporting SNMP Trap Description: “Temp is outside of normal range.”
NT Event ID: 1078 (Hex)0x44350436 (cpqstmsg.dll)
Log Severity: Information (1)
Event Title: Storage System Temperature OK.
Log Message: The temperature in the %6 %7 storage system connected to SCSI bus %5 of the
controller in slot %4 has returned to the normal operating range.
SNMP Trap: cpqSs3TempOk - 8011 in CPQSTSYS.MIB
Symptom: Storage System temperature OK. The temperature status has been set to OK. The storage
system's temperature has returned to normal operating range. It may be reactivated by the
administrator.
User Action: None.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsBoxTempStatus
Supporting SNMP Trap Description: “Storage System temperature ok.”
Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service Event)
Log Severity: Information (1)
Log Message: Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4,
port %5, bay %6 with serial number “%7”, does not have drive threshold monitoring enabled.
Event Identifiers 1101-1199
NT Event ID: 1101 (Hex)0x8435044d (cpqstmsg.dll)