Storage agents 62
•
cpqFcTapeDriveModel
•
cpqFcTapeDriveFWRev
•
cpqFcTapeDriveSerialNumber
•
cpqFcTapeDriveLocation
Supporting SNMP Trap Description: “Cleaning tape needs replacing.”
NT Event ID: 1196 (Hex)0x843504ac (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Recovery Server Option Status Change.
Log Message: Storage system “%4” has a new RSO status of %5.
SNMP Trap: cpqSsExRecoveryServerStatusChange - 8025 in CPQSTSYS.MIB
Symptom: Storage System Recovery Server Option Status Change. The agent has detected a change
in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates
the current status.
User Action: If the RSO status is noSecondary(6) or linkDown(7), Be sure that the secondary server is
operational and that all cables are connected properly. If the RSO status is secondaryRunningAuto(8)
or secondaryRunningUser(9), examine the primary server for failed components.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsChassisName
•
cpqSsChassisTime
•
cpqSsChassisRsoStatus
•
cpqSsChassisIndex
Supporting SNMP Trap Description: “Storage system recovery server option status changed to
[cpqSsChassisRsoStatus].”
NT Event ID: 1197 (Hex)0x843504ad (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Tape Library Status Change.
Log Message: The tape library at location “%4”, has a new status of %7.
SNMP Trap: cpqExtTapeLibraryStatusChange - 16026 in CPQFCA.MIB
Symptom: External Tape Library Status Change. This trap indicates that the agent has detected a
change in the status of an External Tape library. The variable cpqFcTapeLibraryStatus indicates the
current tape library status.
User Action: If the tape library is failed or is offline, check the tape library front panel and all
connections.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqFcTapeLibraryCntlrIndex
•
cpqFcTapeLibraryScsiBus