157
# Enable link-aggregation traffic redirection.
[Sysname] link-aggregation lacp traffic-redirect-notification enable
# Enable the IRF bridge MAC address to be permanent.
[Sysname] irf mac-address persistent always
# Set the physical state change suppression interval to 0 on the interfaces.
[Sysname] interface gigabitethernet1/3/0/1
[Sysname-GigabitEthernet1/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet1/3/0/1] quit
[Sysname] interface gigabitethernet2/3/0/1
[Sysname-GigabitEthernet2/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet2/3/0/1] quit
[Sysname] interface gigabitethernet3/3/0/1
[Sysname-GigabitEthernet3/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet3/3/0/1] quit
[Sysname] interface gigabitethernet4/3/0/1
[Sysname-GigabitEthernet4/3/0/1] link-delay 0 mode updown
[Sysname-GigabitEthernet4/3/0/1] quit
[Sysname] quit
# Upgrade the feature on subordinate member 2. After the upgrade, the subordinate member will
leave the original IRF fabric and form a new IRF fabric by itself.
<Sysname> issu load file feature flash:/soft-version2.bin chassis 2
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Verifying the file flash:/soft-version2.bin on chassis 1 slot 6...Done.
Copying file flash:/soft-version2.bin to chassis2#slot6#flash:/soft-version2.bin
...Done.
Verifying the file flash:/soft-version2.bin on chassis 2 slot 6...Done.
Copying file flash:/soft-version2.bin to chassis2#slot7#flash:/ soft-version2.bin
...Done.
Verifying the file flash:/soft-version2.bin on chassis 2 slot 7...Done.
Upgrade summary according to following table:
flash:/soft-version2.bin
Running Version New Version
Release 7168 Release 7168
Chassis Slot Upgrade Way
2 3 Reboot
2 6 Reboot
2 7 Reboot
Upgrading software images to incompatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# Perform a master/subordinate switchover to upgrade the original master and the other two
subordinate members. The original master and the other two subordinate members will reboot and
join the new IRF fabric.
<Sysname> issu run switchover
Copying file flash:/soft-version2.bin to chassis1#slot7#flash:/soft-version2.bin
...Done.
Содержание FlexNetwork 10500 Series
Страница 139: ...130 Sysname display version ...