222
Step
Command
Remarks
2.
Set the action to be taken in
response to failures on the
forwarding plane to
isolate
.
hardware-failure-detection
forwarding
isolate
By default, the system takes the
action of
warning
(sending traps)
in response to forwarding-plane
failures.
3.
Enter Ethernet interface
view.
interface interface-type
interface-number
N/A
4.
Disable hardware failure
protection for the interface.
undo
hardware-failure-protection
auto-down
By default, hardware failure
protection is enabled.
Configure this command on every
member interface in the
aggregation group.
5.
Exit to system view.
Quit
N/A
6.
Enable hardware failure
protection for aggregation
groups.
hardware-failure-protection
aggregation
By default, hardware failure
protection is disabled for
aggregation groups.
This command is supported only
on the default MDC.
Enabling data forwarding path failure detection
You can enable the device to automatically detect data forwarding path failures and output log
information for notification.
To enable data forwarding path failure detection:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable data forwarding path
failure detection.
forward-path-detection enable
By default, data forwarding path
failure detection is enabled.
This command is supported only
on the default MDC.
Verifying and diagnosing transceiver modules
Verifying transceiver modules
You can use one of the following methods to verify the genuineness of a transceiver module:
•
Display the key parameters of a transceiver module, including its transceiver type, connector
type, central wavelength of the transmit laser, transfer distance, and vendor name.
•
Display its electronic label. The electronic label is a profile of the transceiver module and
contains the permanent configuration, including the serial number, manufacturing date, and
vendor name. The data is written to the storage component during debugging or testing.
Install only transceiver modules that are from Hewlett Packard Enterprise. If you install a transceiver
module that is not from Hewlett Packard Enterprise, the device will generate a log message to ask
you to replace the module. For more information about log messages, see information center
configuration in
Network Management and Monitoring Configuration Guide
.
To verify transceiver modules, execute the following commands in any view: