143
flash:/system-r0201.bin
flash:/feature1-r0201.bin
Active packages on chassis 2 slot 7:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/feature1-r0201.bin
# Identify the ISSU method and possible impact of the upgrade.
<Sysname> display version comp-matrix file feature flash:/feature1-r0202.bin
Verifying the file flash:/feature1-r0202.bin on Chassis 1 slot 6...Done.
Feature image: flash:/feature1-r0202.bin
Version:
V700R001B45D002
Version Compatibility List:
V700R001B45D001
V700R001B45D002
Version Dependency System List:
V700R001B45D001
V700R001B45D002
Chassis Slot Upgrade Way
1 6 Service Upgrade
1 7 Service Upgrade
2 6 Service Upgrade
2 7 Service Upgrade
Influenced service according to following table on chassis 1 slot 6:
flash:/feature1-r0202.bin
feature1 CFA
Influenced service according to following table on chassis 1 slot 7:
flash:/feature1-r0202.bin
feature1 CFA
Influenced service according to following table on chassis 2 slot 6:
flash:/feature1-r0202.bin
feature1 CFA
Influenced service according to following table on chassis 2 slot 7:
flash:/feature1-r0202.bin
feature1 CFA
The output shows that service upgrade is recommended. The feature and its related modules might
reboot during the upgrade.
# Disable automatic rollback.
<Sysname> system-view
[Sysname] issu rollback-timer 0
# Enable link-aggregation traffic redirection.
[Sysname] link-aggregation lacp traffic-redirect-notification enable
# Enable the IRF bridge MAC address to be permanent.
[Sysname] irf mac-address persistent always
# Set the physical state change suppression interval to 0 on the interfaces.
Содержание FlexNetwork 10500 Series