Modifying serial port parameters
When using the console port to access the system, make sure the port parameters are consistent
with the serial port settings on the configuration terminal. Port parameters include the baud rate, data
bits, parity check, stop bits, flow control, and emulation. If the settings are inconsistent,
communication will fail. For more information, see "
Using the console port for the first device
."
For faster file transfer, change the default baud rate to a higher value before downloading a software
image file with XMODEM through the console port.
To change the baud rate of the console port:
1.
Enter
1
in the BASIC-BOOTWARE menu.
Enter your choice(0-5): 1
===============================<BAUDRATE SET>===============================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Available>---------------------------|
|<1> 9600(Default)* |
|<2> 19200 |
|<3> 38400 |
|<4> 57600 |
|<5> 115200 |
|<0> Exit |
============================================================================
Enter your choice(0-5):
2.
Enter the number that represents the baud rate you want to choose. For example, enter
5
to set
the baud rate to 115200 bps.
NOTE:
The baud rate change is a one-time operation. The baud rate will restore to the default (9600 bps) at
reboot. To establish a console session with the device after a reboot, you must change the baud rate
setting on the configuration terminal to 9600 bps.
Updating the extended BootWare segment
If the extended BootWare segment is corrupt, enter
2
in the BASIC-BOOTWARE menu to update it.
Enter your choice(0-5): 2
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCC
Download successfully!
329344 bytes downloaded!
Updating Extended BootWare? [Y/N]Y
Updating Extended BootWare...............Done.
Updating the entire BootWare
To update the entire BootWare, enter
3
in the BASIC-BOOTWARE menu.
Enter your choice(0-5): 3
Please Start To Transfer File, Press <Ctrl+C> To Exit.