31
4. Pump-Out Frequency Control (S4 dip switch 5)
The pump-out frequency control is factory set to drain the water tank every 10 cycles.
Generally no adjustment is required. However, where water quality is bad and the
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The
pump-out frequency control can be set to have a pump-out occur every cycle, or every
10 cycles.
The first pump-out is dependent on S4 dip switch 5. See the table below.
S4 Dip Switch Setting
Pump-Out Frequency
1st Pump-Out
No. 5
OFF
Every 10 cycles
After 11th freeze cycle
ON
Every cycle
After 2nd freeze cycle
5. Harvest Pump Time (Harvest Assist Duration) (S4 dip switch 6)
NOTICE
Factory set for proper operation. Do not adjust. Adjustment outside of the factory
default setting may result in damage to the appliance.
Harvest pump time (harvest assist duration) is only active when S4 dip switch 7 is in
the "ON" position. In the factory default position, the harvest pump time (harvest assist
duration) starts with 50 sec. left to go in harvest cycle (S4 dip switch 6) and after the
thermistor reaches 48°F (9°C) at the evaporator outlet and the control board reads
3.9 kΩ from the thermistor.
The harvest pump time (harvest assist duration) is factory set, and no adjustment is
required.
S4 Dip Switch Setting
Harvest Pump Time
(Harvest Assist)
No. 6
S5-4 OFF
S5-4 ON
OFF
50 sec.
25 sec.
ON
25 sec.
15 sec.