41
2. Remove the water from the water tank:
1) Turn off the power supply, then remove the front panel.
2) Move the control switch to the "OFF" position.
3) Drain the water tank. Remove the rubber cap covering the overflow pipe in the water
tank. Remove the overflow pipe by turning it counterclockwise. After the water tank
has drained, replace the overflow pipe and the rubber cap in their correct positions.
NOTICE
!
Make sure the O-ring is attached to the bottom of the overflow pipe and
be careful not to cross thread the overflow pipe.
4) Replace the base cover (if applicable) and front panel in their correct positions.
5) Remove all ice from the dispensing unit/ice storage bin. Clean the storage bin liner
using a neutral cleaner. Rinse thoroughly after cleaning.
Fig. 3
Rubber Cap
Overflow Pipe
Sleeve
O-Ring
Cube Guide