23
Freeze-Up - Possible Cause
13. Thermostatic Bin Control
See "II.D. Bin Control Check"
a) Defective.
Freeze Cycle
1. Evaporator
a) Scaled up.
b) Damaged.
2. Spray Tubes and/or Spray
Guides
a) Dirty.
b) Out of position.
3. Refrigerant Charge
a) Low.
4. Control Board
See "II.C. Control Board Check"
a) Freeze timer (S4 dip switch 9 & 10) set incorrectly.
b) Defective.
5. Inlet Water Valve
a) Leaking by.
6. Float Switch
See "II.E. Float Switch Check
and Cleaning"
a) Float does not move freely.
b) Defective.
7. Pump Motor
a) RPM too slow.
b) Impeller damaged.
8. Thermostatic Expansion Valve
a) Bulb loose or defective.
9. Liquid Line Valve
a) Restricted.