26
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
NOTICE
On KM-515MAH-E and KM-650MAH-E models: Do not adjust.
Adjustments to this setting may adversely affect performance and warranty coverage.
The pump-out frequency control is factory set to drain the water tank every 10 cycles
on the KM-320MAH-E and every cycle on the KM-515MAH-E and the KM-650MAH-E,
and generally no adjustment is required. However, where water quality is bad and the
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The
pump-out frequency control can be set to have a pump-out occur every cycle, or every
2, 5, or 10 cycles.
Timing of the first pump-out is dependent on the control board. "E" control board first
pump-out is after the first freeze cycle. "G" control board first pump-out is dependent on
S4 dip switch 5 & 6. See the table below.
"E" & "G" Control Board
1st Pump-Out
S4 Dip Switch Setting
Pump-Out
Frequency
"E" Control Board
"G" Control Board
No. 5
No. 6
OFF
OFF
Every cycle
After 1st freeze cycle
After 2nd freeze cycle
ON
OFF
Every 2 cycles
After 3rd freeze cycle
OFF
ON
Every 5 cycles
After 6th freeze cycle
ON
ON
Every 10 cycles
After 11th freeze cycle
e) Bin Control Selector/Harvest Pump Timer (S4 dip switch 7)
Depending on the control board, S4 dip switch 7 is either a bin control selector or harvest
pump timer.
NOTICE
Do not adjust. This dip switch must be left in the factory default position or this
icemaker will not operate correctly.
(1) Bin Control Selector, "E" Control Board
KM-320MAH-E and KM-650MAH-E Auxiliary Code U-0 and Earlier
KM-515MAH-E Auxiliary Code U-1 and Earlier
Factory set for proper operation. Do not adjust. When set to the on position on a
icemaker with a thermostatic bin control, a 5-beep alarm sounds (open circuit) and the
icemaker does not operate.
"E" Control Board
S4 Dip Switch Setting
Bin Control
No. 7
ON
Mechanical
OFF
Thermostatic