(4) Pump-Out Cycle
LEDs 1, 3, and 2 are on.
Comp remains energized. HGV energizes. WV energizes if
S4 dip switch 3 off and 4 on (LED 4 on). LLV (KM-515MAH-E) and FM de-energize.
PM stops for 2 seconds then reverses for 10 or 20 seconds (S4 dip switch 3 & 4).
Water is removed from the bottom of the water tank through the check valve and
down the drain. At the same time, water flows through the small F/S tube to power
flush F/S. When the pump-out timer terminates, pump-out is complete.
The 1st pump-out occurs after the 11th freeze cycle, then every 10th cycle thereafter
(KM-320MAH-E) or every cycle thereafter (KM-515MAH-E and the KM-650MAH-E).
The pump-out frequency control is factory set, and generally no adjustment is
required. However, the pump-out frequency control (S4 dip switch 5 & 6) can be set
to have a pump-out occur every cycle, or every 2, 5, or 10 cycles. For details, see
"II.C.3.d) Pump-Out Frequency Control (S4 dip switch 5 & 6)."
"G" Control Board Settings
S4 Dip Switch Setting
Pump-Out
Frequency
1st Pump-Out
No. 5
No. 6
OFF
OFF
Every cycle
After 2nd freeze cycle
ON
OFF
Every 2 cycles
After 3rd freeze cycle
OFF
ON
Every 5 cycles
After 6th freeze cycle
ON
ON
Every 10 cycles
After 11th freeze cycle
(5) Harvest Cycle
LEDs 1, 4, and 2 are on.
Same as the initial harvest cycle. See "II.B.1.b)(2) Initial
Harvest Cycle."
Note: Icemaker continues to cycle until MBC is satisfied or power is turned off. The
icemaker always restarts at the 1-minute fill cycle.
(6) Shutdown
When MBC is activated (MBC open), the yellow "BC OPEN" LED comes on. The
icemaker then shuts down as outlined in the table below.
Cycle at
Mechanical Bin
Control Activation
Shutdown
Fill Cycle
15 seconds after activation.
Harvest Cycle
At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated
at the end of the harvest cycle.
Freeze Cycle
15 seconds after activation if activated at least 15 seconds before the 5-minute short
cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.
Legend:
CB
–control board;
Comp
–compressor;
FM
–fan motor;
F/S
–float switch;
HGV
–hot gas valve;
LLV
–liquid line valve (KM-515MAH-E);
MBC
–mechanical bin
control;
PM
–pump motor;
WV
–inlet water valve