3. Controls and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the "E" and "G"
control boards:
S4 Dip Switch No. 1
2
3
4
5
6
7
8
9
10
KM-320MAH-E
ON OFF OFF ON ON ON OFF OFF ON ON
KM-515MAH-E
OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
KM-650MAH-E
OFF OFF OFF OFF OFF OFF OFF OFF ON ON
S5 Dip Switch (Do Not Adjust)
"G" Control Board
Dip Switch No.
1
2
3
4
5
KM-320MAH-E
KM-515MAH-E
KM-650MAH-E
OFF OFF OFF OFF OFF
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Bin Control Selector (7) "E" Control Board
Harvest Pump Timer (7) "G" Control Board
(Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
"E" and "G" Control Boards
1
2
3
4
5
ON
Do Not Adjust
S5 Dip Switch
"G" Control Board Only
Refill Counter
(2 through 5)
Float Switch
Selector (1)