2. KM-515MAH-E
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
513
233
482
219
441
200
80/27
490
222
442
200
401
182
90/32
482
219
408
185
366
166
lbs./day kg./day
100/38
474
215
398
181
328
149
70/21
80/27
90/32
watts
100/38
70/21
159
0.60
144
0.55
131
0.50
80/27
148
0.56
125
0.47
115
0.44
90/32
144
0.55
108
0.41
97
0.37
gal./day m
3
/day
100/38
125
0.47
106
0.40
87
0.33
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
245
17.2
267
18.8
294
20.6
80/27
262
18.4
296
20.8
321
22.5
90/32
267
18.8
320
22.5
346
24.3
PSIG kg/cm
2
G
100/38
271
19.1
326
22.9
370
26.0
70/21
50
3.5
54
3.8
57
4.0
80/27
53
3.8
60
4.2
61
4.3
90/32
54
3.8
65
4.6
67
4.7
PSIG kg/cm
2
G
100/38
54
3.8
65
4.6
69
4.9
10,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
28
34
28
29
33
3.0
2.9
3.3
26
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
1118
28
31
1080
1107
1115
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
1115
1161
1200
1207
1150
1189
1231
1260
32
35
37
40
HARVEST CYCLE TIME
HEAD PRESSURE
3.2
3.1
3.2
2.9
2.9
3.4
3.1
3.2
2.9
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE