![Hoshizaki DCM-230FE Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/hoshizaki/dcm-230fe/dcm-230fe_service-manual_2164975050.webp)
50
10) Check for water leaks.
11) Replace the panels in their correct position.
[f] FLOAT SWITCH
WARNING
1. Fragile, handle very carefully.
2. If the Float Switch works poorly because of scale or other foreign matter, install
a filter or softener in the water supply line.
1) Unplug the ice dispenser.
2) Close the water supply tap.
3) Remove the Panels.
4) Open the Drain Valve by rotating the knob , and after draining water, close the Drain
Valve.
5) Cut the Float Switch leads at the wire connectors.
6) Turn the unfasten the flanged top, and remove the Float Switch.
7) Install the new Float Switch.
8) Assemble the removed parts in the reverse order of which they were removed.
9) Open the water supply tap.
10) Plug in the ice dispenser.
Содержание DCM-230FE
Страница 5: ...5 I GENERAL INFORMATION 1 DIMENSIONS CONNECTIONS...
Страница 9: ...9...
Страница 26: ...26 9 Plug in the ice dispenser 10 Check for water leaks 11 Replace the panels in their correct positions Fig 13...
Страница 27: ...27 V TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...
Страница 28: ...28 2 WIRING DIAGRAM...
Страница 29: ...29 3 TIMING CHART...
Страница 46: ...46 Fig 14...