58
Honeywell, Issue 9
March 2007
XLS80e Fire Alarm Control Panels
7.3
Output Categories
Possible output devices or categories in a
Control Matrix entry are shown below.
SPECIFIED
DEVICE
EXTINGUISHING
ACTIV
ATE
OUTPUTS
Restricted- by-type
(b)
CELL
ZONE
Select
Zone(s)
(a)
Select Cell(s)
A
B
D
Select Circuit
Select Module
CONTROL
MA
TRIX
OUTPUTS
Select Zone
Select
Select Flag
TRANSFER
FLAG
ALL
OUTPUTS
SOUNDER/
RELA
Y
CIRCUIT
Steady/Pulsing
(NOT
applicable
if
input
is
DISABLEMENT
,
RESET*,
SILENCE*
or
MCP
in
walk
test*)
Delay
(NOT
applicable
if
input
is
DISABLEMENT
,RESET
,
SILENCE
or
MCP
in
walk
test.
EXTINGUISHING:
see
note
[c])
TIME
OF
DA
Y
Select
END
OF
ENTR
Y
All
times
(not
applicable
if
input
is
TRUE)
All
times
Logic
Output
(f)
No Logic
Select System
Select Alarm
Operation
Soak
(if
applicable
to
selected Alarm
Operation)
SPECIFIED
DEVICE
EXTING- UISHING
ACTIV
ATE
OUTPUTS
Restricted- by-type
(b)
CELL
ZONE
Select Zone(s)
(a)
Select Cell(s)
C
Select Circuit
Select Module
Select Zone
DISABLE
ACTIONS
ALL
OUTPUTS
SOUNDER/
RELA
Y
CIRCUIT
Steady/Pulsing
TIME
OF
DA
Y
Select
END
OF
ENTR
Y
Select System
Select
Non-Alarm Operation
Timer
adjust
(available
for
some
Non-Alarm Operations
only)
Select Flag
OTHER
Logic
Output
(f)
No Logic
SPECIFIED
DEVICE
ZONE(S)
(d)
SOUNDER/
RELA
Y
CIRCUIT
Sensor/ Module
Select Zone
Select Zone
Select Device
Select Circuit
Select Zone(s)
MUTE BUZZER SILENCE
SOUNDERS
SYSTEM RESET
TRANSFER
FLAG
(f)
INPUT
:
ALARM (including
Thermal-only
Alarm)
INPUT
:
PRE-ALARM
FAUL
T
DISABLEMENT
EV
ACUA
TE
TRANSFER
FLAG
INPUT
:
EXTINGUISHING RESET SILENCE MCP
in
walk
test
INPUT
:
NON-FIRE
(a)
If
ANY
ZONE
is
selected,
the
internal
sounder
circuit
s
are
included.
(b)
Sounders
3
&
4
can
be
configured
as
volt-free
relays,
but
are
referred
to
as
Sounders
in
the
control
matrix.
Selecting
ALL
OUTPUT
MODULES
will
drive
sounders
1-4,
even
if
3
or
4
are
set
as
relays.
ALL
SOUNDER
OUTPUTS
will
drive
sounders
1
and
2,
and
3
and
4
only
if
they
are
configured
as
sounders.
ALL
CONTROL
OUTPUTS
will
drive
sounders
3
and
4
only
if
they
are
configured
as
relays.
(c)
If
the
is
ALARM
and
the
is
EXTINGUISHING
,and
depending
upon
which
alarm
operation
is
selected,
a
special
'activation
delay'
range
is
provided.
(d)
The
'Disablement
from
a
remote
panel
or
switch'
option
in
the
Panel
Settings
'Disablement
Options
'menu
determines
what
is
disabled
in
the
zone
(sensors
only
,all
input
s
[default]
or
all
input
s
and
output
s).
(e)
Available
only
if
at
least
one
Multi-criteria
sensor
has
been
configured
for
'Thermal
Mode
by
Zone'.
(f)
TRANSFER
FLAG
also
available
when
input
is
TRUE.
'Logic
Output
'available
only
if
the
input
is
ALARM,
PRE-ALARM,
NON-FIRE,
another
TRANSFER
FLAG
or
TRUE.
(g)
Action
occurs
only
when
input
is
switched
from
open
to
closed.
input
output
Note:
The
output
zone
does
not
have
to
be
the
same
as
the
input
zone.
E
INPUT
:
TRUE
*
=
single
pulse
SET TO
THERMAL-
ONL
Y
MODE
(e)
Select Zone(s)
NIGHT
MODE
(g)
DA
Y
MODE
(g)
EXTEND DELA
Y
(g)
OVER-RIDE DELA
Y
(g)
VIR
TUAL
OUTPUT POINT
Select Point
Mode 1o
r2
VIR
TUAL
OUTPUT POINT
Select Point
Mode 1o
r2
VIR
TUAL
OUTPUT POINT
Select Point