7.1
Drive power ratings
7.1.1
Mains voltage 208-240 V
Table 28. Power ratings, supply voltage 208-240V.
NOTE:
The rated currents in given ambient temperatures (in Table 30) are achieved only when
the switching frequency is equal to or less than the factory default.
Mains voltage 208-240V, 50-60 Hz, 3~
Product
type
Loadability
Motor shaft power
Low
*
*
See chapter 7.1.3.
230 supply
208-240V supply
Rated continuous
current I
L
[A]
Input
current I
in
[A]
10% overload
current
[A]
10% overload
40°C
[kW]
10% overload
40°C
[hp]
MR4
230 P55
3.7
3.2
4.1
0.55
0.75
230 P75
4.8
4.2
5.3
0.75
1.0
230 1P1
6.6
6.0
7.3
1.1
1.5
230 1P5
8.0
7.2
8.8
1.5
2.0
230 2P2
11.0
9.7
12.1
2.2
3.0
230 3P0
12.5
10.9
13.8
3.0
4.0
MR5
230 4P0
18.0
16.1
19.8
4.0
5.0
230 5P5
24.2
21.7
26.4
5.5
7.5
230 7P5
31.0
27.7
34.1
7.5
10.0
MR6
230 11P
48.0
43.8
52.8
11.0
15.0
230 15P
62.0
57.0
68.2
15.0
20.0
MR7
230 18P
75.0
69.0
82.5
18.5
25.0
230 22P
88.0
82.1
96.8
22.0
30.0
230 30P
105.0
99.0
115.5
30.0
40.0
MR8
230 37P
143.0
135.1
154.0
37.0
50.0
230 45P
170.0
162.0
187.0
45.0
60.0
230 55P
208.0
200.0
225.5
55.0
75.0
MR9
230 75P
261.0
253.0
287.1
75.0
100.0
230 90P
310.0
301.0
341.0
90.0
125.0