4
ELECTRICAL CONNECTIONS
48
RM640
www.honeywellprocess.com
34-VF-25-131 iss.1 GLO Feb 2019 US
4.3 Electrical installation: output options with cable gland
Figure 4-1: Terminals for electrical installation: standard cable gland
1
Grounding terminal in the housing (if the electrical cable is shielded)
2
Current output -
3
Current
4
Location of the external grounding terminal (at the bottom of the converter)
INFORMATION!
Electrical power to the output terminal energizes the device. The output terminal is also used for
HART
®
communication.
CAUTION!
•
Use the applicable electrical cables with the cable glands.
•
Make sure that the current is not more than 5 A or that there is 5 A-rated fuse in the
electrical circuit that energizes the device.