INSTALLATION
3
39
RM640
www.honeywellprocess.com
34-VF-25-131 iss.1 GLO Feb 2019 US
7
If the antenna extension is supplied after delivery of the device, it is necessary to change the
device settings. Do the procedure that follows.
Procedure 2: Device settings for a device with an antenna extension
•
Push 2 × [>>>>], 2 × [
] and [>>>>] to go to menu item Login
Login
Login
Login.
•
Enter the hexadecimal password (default password: 0058).
•
Push 2 × [
^
^
^
^
], 2 × [
], 2 × [>>>>], 5 × [
] and [>>>>] to go to menu item C 1.8 Antenna Extension
C 1.8 Antenna Extension
C 1.8 Antenna Extension
C 1.8 Antenna Extension.
•
Push [>>>>] to change the value. Push [>>>>] to change the position of the cursor. Push [
] to
decrease the value or [
] to increase the value.
i
Each antenna extension is 105 mm long. If the device has 3 antenna extensions, they have a
total length of 315 mm. In this example, enter the value "315".
•
If you changed the antenna extension value, also change the blocking distance value. Push
[
^
^
^
^
], 3 × [
], [>>>>] to go to menu item C1.5 Blocking Distance
C1.5 Blocking Distance
C1.5 Blocking Distance
C1.5 Blocking Distance.
•
Push [>>>>] to change the value. Push [>>>>] to change the position of the cursor. Push [
] to
decrease the value or [
] to increase the value. Minimum recommended blocking distance =
antenna (antenna extension length × number of extensions) + 0.3 m / 12
¨
.
•
Push 3 × [
^
^
^
^
] to go back to the "Save Configuration?" screen.
•
Push [
] or [
] to set the screen to Yes
Yes
Yes
Yes and push [
^
^
^
^
] to store and use the changed settings.
i
End of the procedure.
3.9 Orientation system (accessory)
3.9.1 How to attach the orientation system to the device
If it is necessary to tilt the antenna at the product with angle more than 2
°
from the vertical axis,
attach an orientation system to the device. This part is available as an accessory for devices with
threaded connections. The orientation system has a low pressure flange to attach the device to
silo.
WARNING!
If the orientation system is attached to the device, do not pressurize the silo. Use only at
atmospheric pressure.
Device with a metallic horn antenna
Figure 3-16: Device with a metallic horn antenna
Содержание RM640
Страница 4: ...4 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ABOUT THIS DOCUMENT RM640 ...
Страница 20: ...1 SAFETY INSTRUCTIONS 20 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 56: ...4 ELECTRICAL CONNECTIONS 56 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 120: ...6 OPERATION 120 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 164: ...9 DESCRIPTION OF HART INTERFACE 164 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 182: ...10 APPENDIX 182 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 183: ...APPENDIX 10 183 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...