3
INSTALLATION
34
RM640
www.honeywellprocess.com
34-VF-25-131 iss.1 GLO Feb 2019 US
•
Metallic Horn antennas without an antenna extension:
Metallic Horn antennas without an antenna extension:
Metallic Horn antennas without an antenna extension:
Metallic Horn antennas without an antenna extension: Attach the locking screw to the antenna
with a 3 mm Allen wrench.
•
All antennas with one or more antenna extensions:
All antennas with one or more antenna extensions:
All antennas with one or more antenna extensions:
All antennas with one or more antenna extensions: Attach the locking screw to the top
antenna extension with a 3 mm Allen wrench.
•
Put the device carefully on the silo flange.
•
Make sure that you point the device in the correct direction. For more data, refer to
General
notes
on page 28 ("Point the device in the correct direction").
•
Tighten the flange bolts. Refer to local rules and regulations for the correct torque to apply to
the bolts.
i
End of the procedure.
Recommended socket size for threaded connections
The socket must be as short as possible. If the socket is in a recess, then use the maximum
limits for nozzle dimensions (flange connections) in this section.
If the device has antenna extensions, this option extends the maximum socket height. Add the
length of the antenna extensions attached to the device to this value.
Equipment needed:
•
Device
•
Gasket for G 1
½
connection (not supplied)
•
Thread seal tape (PTFE) for 1
½
NPT connection (not supplied)
•
50 mm open-end wrench (not supplied)
INFORMATION!
Antenna extensions for devices with flanges
Antenna extensions for devices with flanges
Antenna extensions for devices with flanges
Antenna extensions for devices with flanges
If the device has antenna extensions, this option extends the maximum nozzle height. Each
antenna extension has a length of 105 mm / 4.1
¨
. The maximum number of antenna extensions
that can be attached to the device are:
•
Metallic Horn antenna: 10
•
PP Drop antenna: 5
•
PTFE Drop antenna: 5
Threaded connections: installation procedure
Figure 3-12: Threaded connections: installation procedure
Содержание RM640
Страница 4: ...4 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ABOUT THIS DOCUMENT RM640 ...
Страница 20: ...1 SAFETY INSTRUCTIONS 20 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 56: ...4 ELECTRICAL CONNECTIONS 56 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 120: ...6 OPERATION 120 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 164: ...9 DESCRIPTION OF HART INTERFACE 164 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 182: ...10 APPENDIX 182 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Страница 183: ...APPENDIX 10 183 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...