8
IC
Idle Count Parameter
Set IC parameter *00WE
(set idle count to 12 , so that 12 output samples are skipped)
*00IC=12
Inquiry *00IC
?01IC=12
I
D
Identification Number
Set ID number *00WE
(set device ID of first null addressed unit to 12)
*00ID=12
Confirmation of ID=12 *12P1
#12CP= 14.32
Set group number *12WE
[Ring Network]
(set group ID of unit 12 to 95)
*12ID=95
[Ring Network]
Group no. inquiry of device ID=12 *12ID
#12ID=95
[Multi-Drop]
(set group ID of unit 12 to 95 with group sub-address of 01)
*12ID=9501
[Multi-Drop] Group no. inquiry of device ID=12 *12ID
#12ID=9501
IN
Initialize HPB Microprocessor
Stop all current operations *99IN
(does not affect RAM data)
Full reset of HPB processor *99IN=reset
Changes to RAM data are lost unless an SP =ALL command
was previously issued. (Response is user message, if selected) ?01Pressure_tank_1
I=
Integration time
Set I parameter *00WE
(set output rate to 50 readings/second)
*00I=R50
Inquiry *00I=
?01I=R050
M=
Maximum Full Scale Value Allowed
(Factory set)
Inquiry *00M=
?01M=0017psia
MO Power Up Mode
Set MO parameter *00WE
*00MO=M1
*00WE
Required to save in EEPROM for power-up *00SP=ALL
Inquiry *00MO
?01MO=X2M1
OP
Operating Mode Parameters
Set OP parameter *00WE
(set to extended binary output mode)
*00OP=E
Inquiry *00OP
?01OP=ANEW
P1
Pressure, Single, ASCII Format
Request compensated pressure *00P1
?01CP= 14.450
P2
Pressure, Continuous, ASCII Format
Request compensated pressure *00P2
?01CP= 14.450
(repeated)
P3
Pressure, Single, Binary Format
Compensated pressure (null address) *00P3
^@PSA or
Compensated pressure (assigned address) *01P3
{@PSA
(typical response is a ^ or { char plus 4 data bytes
that are encoded for computer translation)
Note: See Section 5.10 for complete command descriptions.
Example
Example
Input (1)
Response (2)