5
TRY OTHER COMMANDS
Experiment with other commands to become familiar with the command structures. A short overview of each command
with input and response examples is shown in Section 3 Commands Quick Reference. See Section 5Commands
for complete command descriptions. Until an
SP=ALL
command is executed, no changes will be stored in the
EEPROM. Cycle the power or send an
IN=RESET
command to revert to previous EEPROM settings.
2.7 Command Functional Groups
PRESSURE DISPLAY UNITS
HPB reads out psi, in wc, mm Hg, etc.
DU
Set pressure units for output readingsany one of 17 units
U=
Specify a user supplied unit of measure
TEMPERATURE
T1
Single °C
T2
Continuous °C
T3
Single °F
T4
Continuous °F
RING/MULTI-DROP BUS PARAMETERS
BP
Changes baud rate and parity
ID
Assign device ID and group addresses
M=
Select alternate message Headers [Multi-Drop]
SI
Synchronize Integration cycles among units [Multi-Drop]
TO
Set Transceiver Operating parameters
OUTPUT READING AND RATE
Speed up or slow down output rate
Single Reading Commands
P1
Single pressure reading...ASCII format
P3
Single pressure reading...binary format
T1
Single temperature reading...°C
T3
Single temperature reading...°F
Continuous Readings Commands
P2
Continuous pressure readings...ASCII format
P4
Continuous pressure readings...binary format
T2
Continuous temperature readings...°C
T4
Continuous temperature readings...°F
Integration Time Commands
Changes pressure reading response time
DS
Set deadband and sensitivity parameters
I=
Set pressure integration time and reading rate
SI
Synchronize pressure Integration cycles
Idle Count Command
Changes pressure reading response time
ICSet number of idle integration cycles
Reading Response To Changes In Input Pressure
Filters small changes
RR
Set number of identical readings to skip
OP
Transmit all readings or only changed readings