Section 4: Registration
4-3
Registration BAD
Pri&Sec – IDs BAD
Displayed when both primary and secondary subscriber IDs are
invalid.
Registration BAD
Pri ID – Need PIN
Displayed if this is a repair
/
replacement, or an error was made in
programming the Primary account information of IGSMHS for an
existing account. This prompt appears for 2 seconds. See the
Replacing an existing module
section below for further displays.
Registration BAD
2nd ID – Need PIN
This prompt is displayed if this is a repair
/
replacement, or an error
was made in programming the Secondary account information of
IGSMHS for an existing account. This prompt appears for 2
seconds. See the
Replacing an existing module
section below for
further displays.
Registration BAD
Pri&2nd – Need PIN
This prompt is displayed if this is a repair
/
replacement, or an error
was made in programming BOTH the Primary and Secondary
account information of
IGSMHS for an existing account. This prompt appears for 2
seconds. See the
Replacing an existing module
section below for
further displays.
Replacing an existing module using the programming tool
Enter PIN#
This prompt appears after pressing the [Shift} and down arrow
[
]
on the 7720P.
NOTE:
If it is necessary to exit registration mode, press ESC from
the 7720P programming tool.
Enter a 4-digit alphanumeric PIN number provided by your central
station, your dealer or an authorized AlarmNet representative.
Press the [Enter] key.
Registering …
The registration message is sent and the unit waits for
acknowledgement.
Registration
SUCCESS
If the PIN is valid, the new IGSMHS is registered and the old unit
unregistered. Additionally, AlarmNet sends a substitution alarm to
the central station.
Registration BAD
If you entered an invalid PIN, the appropriate message is displayed
depending on which account number is being replaced (see above for
exact wording). The registration process is repeated.
NOTE:
Each attempt causes a substitution alarm to be sent to the
central station.
Register by Phone
You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at
1-800-222-6525. You will need the following information:
MAC number (found on the label).
Subscriber information (provided by the central station), including a city code, CSID, and
a subscriber ID.
When instructed to do so, triple-click the tamper switch to complete the registration.
Содержание AlarmNet IGSMHS
Страница 2: ......
Страница 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Страница 18: ......
Страница 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Страница 44: ...IGSMHS Installation and Setup Guide 4 4 ...
Страница 52: ...IGSMHS Installation and Setup Guide A 2 ...
Страница 54: ...IGSMHS Installation and Setup Guide B 2 ...
Страница 58: ...IGSMHS Installation and Setup Guide D 2 ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...