Section 3: Programming the IGSMHS
3-9
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
48
Review? Y/N
[Y] = review
[N] = exit
Reviewing Programming Mode Entries
To review the programming options (to ensure that
the correct entries have been made), press [Y]. The
programming prompts are displayed again. Use the
up/down arrow keys to scroll through the program
fields without changing any of the values. If a value
requires change, simply type in the correct value.
When the last field is displayed, the “REVIEW?”
prompt again appears.
To exit the programming mode
, press [N] in
response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode
at the end of this section.
ECP Status Codes
When the IGSMHS is configured for ECP mode, it sends status messages to the control
panels for battery, power, tamper, and network connectivity failures. Some control panels
display these on the keypad as “LngRng Radio” followed by a 4-digit code (listed in the table
below). In addition, the Contact ID codes (listed in Appendix B) for these conditions are sent
to the central station by the module.
UL
The information in the following table is based on the VISTA-20 which has not been evaluated
with this communication module.
Table 3-3. Common ECP Keypad Display Status Codes
STATUS CODE
DESCRIPTION
0000
Control panel lost communication with IGSMHS.
0880
IGSMHS tamper detected (cover removed).
4005
IGSMHS has lost contact with AlarmNet.
000F
IGSMHS is not registered; account not activated.
0019 IGSMHS
shutdown.
0400
IGSMHS power on / reset AND the control panel lost communications with IGSMHS.
0C80
IGSMHS power on / reset AND tamper detected.
0C8F
IGSMHS power on / reset AND tamper detected AND not registered.
08E0
IGSMHS tamper detected and IGSMHS battery low.
3000
Primary power loss (will only be displayed in conjunction with another event).
8000
Battery charger failure (will only be displayed in conjunction with another event).
0060
Low battery (will only be displayed in conjunction with another event).
Alternative Modes (Zone Trigger, 4204 and Two-4204)
UL
The LYNX controls have not been evaluated with this communication module.
Zone Trigger Mode
There are six input zones available on the IGSMHS. Each zone is selectable for +V, -V, or
EOLR trigger. The first zone input can detect both pulsed and steady signals if connected to
a bell output. Additionally, the first zone input can be programmed to detect a single pulse
(characteristic of a Panic indication on the Lynx, LynxR or LynxR-EN control panel by
enabling the Lynx Panic option). If the programming option “Lynx Panic” is enabled, the
IGSMHS reports an alarm on zone 3. No restores are reported for this zone. If this option is
selected, the second physical zone input is ignored.
Содержание AlarmNet IGSMHS
Страница 2: ......
Страница 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Страница 18: ......
Страница 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Страница 44: ...IGSMHS Installation and Setup Guide 4 4 ...
Страница 52: ...IGSMHS Installation and Setup Guide A 2 ...
Страница 54: ...IGSMHS Installation and Setup Guide B 2 ...
Страница 58: ...IGSMHS Installation and Setup Guide D 2 ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...