IGSMHS Installation and Setup Guide
3-4
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
3
Program Device?
(Y/N)_
[Y], [N ]
To begin programming the module, press [Y] and go to
Prompt 10: "Device Mode."
To create a password if none has been assigned, press
[N] and go to Prompt 4: "Create Password."
To change an existing password, press [N] and go to
Prompt 5: "Change Password."
4
Create Password?
(Y/N)_
[Y], [N]
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
If a password is desired, press [Y] and go to "Enter
Password."
5
Change Password?
(Y/N)_
[Y], [N]
If a password has already been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
Press [Y] if you want to change the password.
NOTE:
To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key when
prompted for the new password and its confirmation.
6
Enter Password
[0-9, A-F, N, S,
T, X, Y]
This prompt is displayed if [Y] was pressed in Prompt
4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
7
Verify Password
[0-9, A-F, N, S,
T, X, Y]
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the
Exiting Programming Mode
paragraph in
this section.
9
Comm Path
Choice
(IP&GSM)_
IP&GSM
IP
GSM
Press the [space] key to scroll through the
communication path choices. Press [ENTER] to
select.
For maximum reliability, select IP&GSM, and ensure
the Internet is connected using the Ethernet cable.
NOTE:
After going from a “GSM” only com path
choice to an “IP” only choice, Prompt 41: “DHCP” will
default to No.
10
Device Mode
(ECP)_
ECP
Zone Triggers
4204 Emu
Two 4204s
Press the [space] key to scroll through the modes of
operation. Press [ENTER] to select
ECP
mode.
See
Table 3-4
if programming other modes.
Important Information Regarding Primary and Secondary Accounts (Prompts 11-17)
Account information is provided by the central station administrator. If the control panel
supports secondary account reporting, you will need secondary account information. The City ID,
CS ID or Subscriber ID of the secondary account must differ from that of the primary account.
Содержание AlarmNet IGSMHS
Страница 2: ......
Страница 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Страница 18: ......
Страница 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Страница 44: ...IGSMHS Installation and Setup Guide 4 4 ...