Section 3: Programming the IGSMHS
3-17
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY
OPTIONS
DESCRIPTION
36
Restore Zn2 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 2.
UL:
Must be set to “Y.”
37
Delay Zn2 (secs)
(00)_
[01-15]
[00] = no
delay
Defines the reporting delay in seconds for
zone 2.
UL:
Must be set to 00.
38
Rpt Zn2 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
If Lynx Panic is enabled, then skip to Prompt 43: "Rpt Zn3 ONLY if Armed."
39
Zn3 Trigger Type
(V+)_
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone
input. Press the [space] key to scroll through
choices.
UL:
V+ must be set as inverted and V– as
non-inverted.
40
Invert Zn3 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
41
Restore Zn3 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 3.
UL:
Must be set to “Y.”
42
Delay Zn3 (secs)
(00)
[01-15]
[00] = no
delay
Defines the reporting delay in seconds for
zone 3.
UL:
Must be set to 00.
43
Rpt Zn3 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode:
If any zone is programmed to
"Report Only if Armed," skip to Prompt 54:
"Enable Zn6."
44
Zn4 Trigger Type
(V+)_
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone
input. Press the [space] key to scroll through
choices.
UL:
V+ must be set as inverted and V– as
non-inverted.
45
Invert Zn4 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
46
Restore Zn4 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 4.
UL:
Must be set to “Y.”
47
Delay Zn4 (secs)
(00)
[01-15]
[00] = no
delay
Defines the reporting delay in seconds for
zone 4.
UL:
Must be set to 00.
48
Rpt Zn4 ONLY if
Armed (N)_
2-
4204
only
[Y], [N]
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
Содержание AlarmNet IGSMHS
Страница 2: ......
Страница 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Страница 18: ......
Страница 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Страница 44: ...IGSMHS Installation and Setup Guide 4 4 ...
Страница 52: ...IGSMHS Installation and Setup Guide A 2 ...
Страница 54: ...IGSMHS Installation and Setup Guide B 2 ...
Страница 58: ...IGSMHS Installation and Setup Guide D 2 ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...