HLP-C100 Series Operating Manual
HLP-C100 Series
-
42
-
C03.12
Function Description
Range
Unit Default Setting
Catch up/Slow down Value 0.00~100.00 %
0.00
Function: This parameter enables the entry of a percentage value (relative)
which will to be either added to or deducted f rom the actual reference.
Description of Choice: The Catch up/Slow down f unction is activated by a
digital input terminal (See C05.1*, choose [28]/ [29] ). If this f unction
is active, the catch up/slow down value will be added to the actual
reference constituting new setting at which the f requency converter is
going to run, calculated as follows:
Total reference= reference ±reference × (Catch up/Slowdown value) If
this f unction is inactive, the reference returns to its original value (the
actual reference).
For example: Set C05.12=28, C05.13=29, C03.12=30, assuming the actual reference
value is 20 Hz, when only DI1 is on, the output f requency is 26 Hz,
when only DI2 is connected, the output f requency is14Hz, when both
DI1 and DI2 are on, the output f requency is 20Hz.
C03.11
Function Description
Range
Unit
Default Setting
Jog Speed
0.0~400.0
Hz
5.0
Function: Jog f requency is a f ixed f requency that the drive supplies to the
motor af ter the jog f unction is actived. Please refer to C05.1*, select [14].
Description of Choice: The f requency converter with the highest priority
will operate at jog speed when a variety of run command activates.
Removing the jog signal makes the f requency converter run according
to the selected con
fi
guration, this parameter is set limited by C04.14.
Binary system
bit2
bit1
bit0
Preset Reference
Terminals State
0
0
0
0
0
0
1
1
0
1
0
2
0
1
1
3
1
0
0
4
1
0
1
5
1
1
0
6
1
1
1
7