Option: [0] Disable, continue regulation of a given error even when the output
f requency can’t be increased/decreased.
[1] Enable, ceases regulation of a given error when the output
f requency can’t be increased/decreased.
Function: This f unction ensures the output f requency reaches to f requency
limit. PI-controller will be initialized to the current f requency when
the output f requency can not be changed. This can prevent the
integrator continue to integrate on an error when the PI-controller
can’t adjust output f requency.
Function: This reference value corresponding to potentiometer turned f ully
counterwise .
C06.81 Function Description
Range
Unit Default Setting
LCP Potmeter Low
Ref.
-4999.000~4999.000
0.000
Function: This reference value corresponding to potentiometer turned f ully
clockwise.
C06.82 Function Description
Range
Unit Default Setting
LCP Potmeter High
Ref.
-4999.000~4999.000
50.000
Option: [0] No Function;
[1] Analog in VI(0-10 V
、
0-20 mA
、
4-20 mA);
[11] Local Bus (0 ~ ± 200%);
Function: Select resource of feedback signal.
7.8 Parameter Group 07: Controller
C07.20
Function Description
Range
Unit Default Setting
Process CL Feedback 1
0~11
0
C07.2* Process Ctrl. Feedb
C07.31
Function Description
Range
Unit
Default Setting
Process PI Anti Windup
0~1
1
C07.3* Process PI Ctrl.
This parameter is active in closed loop process control mode.