HLP-C100 Series
HLP-C100 Series Operating Manual
-
33
-
Chapter 7 Parameter Description
7.1 Parameter Group 00: Operation/Display
C00.04 Function Description
Range
Unit
Default Setting
Operaton State at
Power-up(Hand)
0~2
1
Option: [0] Resume, local reference is stored and used af ter power up;
[1] Forced stop, ref =old, local reference is stored and used af ter power
up;
[2] Forced stop, ref =0, local reference is set to 0;
Function: This parameter is used to control whether or not the f requency
converter should automatic running the motor when powering up
af ter a power down in Hand mode.
Description of choice: When select “[0]”, f requency converter starts in
same Hand mode roof state as when powered off; When select“[1]”,
f requency converter powers up in off state meaning that motor is
stopped af ter power up; When select“[2]”, f requency converter powers
up in off state meaning that motor is stopped af ter power up. Local
reference is set to 0. Thus motor will not start running before local
reference has been increased.
C00.0* Basic Settings
C00.33 Function Description
Range
Unit
Default Setting
LCP Display Option
0~2047
0
Description of the choice: LCP will be
fi
xed to display the output f requency
、
reference and motor current. This parameter is used to show 11 basic
operating states of the inverter, each parameter corresponds to a binary
code: “1” means display the item, “0” means does not display the item.
For example, if you want to display the states of the temperature and
the terminal VI on LCP. Transform the binary code to decimal digit,
C00.33=1×2
3
+1×2
4
=24.
C00.3* LCP Readout
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
VI
In
pu
t
Te
m
pe
ra
tu
re
DC-
vo
lta
ge
Mo
to
r S
pe
ed
Mo
to
r V
olt
ag
e
0
0
0
0
0
0
1
1
0
0
0
Содержание HLP-C100 Series
Страница 2: ...HLP C100 Series Operating Manual...
Страница 3: ......
Страница 25: ...HLP C100 Series Operating Manual HLP C100 Series 20 4 2 6 LED Display...