Receive data
Transmit data
Receive data
Field
Description
01
FC address
0F
Function
00 00
Register address 0 is f requency converter control word.
00 20
The bit number is 32.
54 13
CRC check
12.7 Preset Multiple Regs
Example: Set C03.03 = 60.000
Transmit: 01 10 0B D5 00 02 04 00 00 EA 60 02 B4 (Hexadecimal)
Receive: 01 10 0B D5 00 02 52 14 (Hexadecimal)
12.8 Read/Write array
Example: write parameter 310[2] (index=2)
Transmit: 01 06 00 08 00 02 89 C9 (Hexadecimal)
Receive: 01 06 00 08 00 02 89 C9 (Hexadecimal)
Field
Description
01
FC address
10
Function
0B D5
The register address of C03.03 is 303*10-1=3029 (0x0BD5)
00 02
Register number
04
The byte number of data is 4
00 00 EA 60
0x0000EA60 convert to decimal number is 60000. So the value
of C03.03 is 60000*0.001=60.000
02 B4
CRC check
Field
Description
01
FC address
10
Function
0B D5
The register address of C03.03 is 303*10-1=3029 (0x0BD5)
00 02
Register number
52 14
CRC check