4-47
Chapter 4
For parameter configuration
[HA230]
~
[HA254]
2nd motor
When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Range
(unit)
Initial
value
HA210
Stabilization constant, 2nd-motor
0
~
1000(%)
100
HA215
Speed response, 2nd motor
Same as HA115
HA220
ASR gain switching mode selection,
2nd-motor
Same as HA120
HA221
Gain switching time, 2nd-motor
Same as HA121
HA222
ASR gain mapping intermediate
speed 1, 2nd-motor
Same as HA122
HA223
ASR gain mapping intermediate
speed 2, 2nd-motor
Same as HA123
HA224
ASR gain mapping Maximum speed,
2nd-motor
Same as HA124
HA225
ASR gain mapping P-gain 1,
2nd-motor
Same as HA125
HA226
ASR gain mapping I-gain 1,
2nd-motor
Same as HA126
HA227
ASR gain mapping P-gain 1 at
P-control, 2nd-motor
Same as HA127
HA228
ASR gain mapping P-gain 2,
2nd-motor
Same as HA128
HA229
ASR gain mapping I-gain 2,
2nd-motor
Same as HA129
HA230
ASR gain mapping P-gain 2 at
P-control, 2nd-motor
Same as HA130
HA231
ASR gain mapping P-gain 3,
2nd-motor
Same as HA131
HA232
ASR gain mapping I-gain 3,
2nd-motor
Same as HA132
HA233
ASR gain mapping P-gain 4,
2nd-motor
Same as HA133
HA234
ASR gain mapping I-gain 4,
2nd-motor
Same as HA134
[Hb102]
~
[Hb108]
Basic parameters for Induction motor
Code/Name
Range (unit)
Initial value
In
du
ct
io
n
m
ot
or
(I
M
)
Hb102
Async.
Motor capacity
setting, 1st-motor
0.01
~
630.00
(kW)
Motor capacity setting
Hb103
Async.
Motor poles
setting, 1st-motor
2
~
48 (Pole)
4
Hb104
Async.
Motor Base
frequency setting,
1st-motor
10.00
~
590.00
(Hz)
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hb105
Async.
Motor Maximum
frequency setting,
1st-motor
10.00
~
590.00
(Hz)
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hb106
Async.
Motor rated
voltage, 1st-motor
1
~
1000 (V)
(200V Class)
200(JPN)
230(EU)(USA)(ASIA)(CHN)
(400V Class)
400(JPN)(EU)(ASIA)(CHN)
460(USA)
Hb108
Async.
Motor rated
current,
1st-motor
0.01
~
10000.00
(A)
Motor capacity setting
・
If the motor capacity [Hb102] and number of poles
[Hb103] are changed, the motor characteristics are set
according to the internal Hitachi table values.
・
The output is decided by setting the frequency and
voltage. Below there is an example of V / f control.
・
By setting the motor rated current, a reference current
for the motor protection is set.
※
Initial value depends on the inverter.
Motor typical data
Code
Range of values (Unit)
Capacity
[Hb102]
0.01
~
630.00 (kW)
Number of poles
[Hb103]
2
~
48 (poles)
Frequency
[Hb104]
10.00
~
590.00 (Hz)
[Hb105]
10.00
~
590.00 (Hz)
Voltage
[Hb106]
1
~
1000 (V)
Current
[Hb108]
0.01
~
9999.99 (A)
Output
voltage
Motor rated
voltage
(Ex.)200V
Command
frequency (Hz)
Base frequency
(Eg.)60Hz
Maximum
frequency