4-58
Chapter 4
For parameter configuration
[PA-01]
~
[PA-09]
■
Parameter mode (P code)
Em-force mode settings
Code/Name
Range (unit)
Initial
value
Em
-f
or
ce
m
od
e
PA-01
Mode selection
for emergency force drive
00(Disable)/
01(Enable)
00
PA-02
Frequency
reference setting oat
emergency force drive
00(Speed control)/
01(PID control)
00
PA-03
Direction
command at
Emergency-force drive
0.00
~
590.00(Hz)
0.00
By
pa
ss
m
od
e
PA-04
Commercial
power supply bypass
function selection
00(Disable)/
01(Enable)
00
PA-05
Delay time of
bypass function
0.0
~
1000.0(s)
5.0
・
Settings for EM-force in case of abnormality.
For more information, refer to the user’s guide.
[PA-20]
~
[PA-29]
Simulation mode settings
Code/Name
Range (unit)
Initial
value
PA-20
Simulation
mode enable
00(Disable)/01(Enable)
00
PA-21
Error code selection
for Alarm test
001
~
255
000
PA-22
Output
current monitor
optional output
enable
00(Disable)/
01(Enable: [Ai1])/
02(Enable:[Ai2])/
03(Enable:[Ai3])/
04(Enable:[Ai4])/
05(Enable:[Ai5])/
06(Enable:[Ai6])/
09(Enable:[PA-23])
01
PA-23
Output
current monitor
optional output value
setting
0.0
~
300.0(%)
0.0
PA-24
DC-bus
voltage monitor
optional output value
selection
00(Disable)/
01(Enable:[Ai1])/
02(Enable:[Ai2])/
03(Enable:[Ai3])/
04(Enable:[Ai4])/
05(Enable:[Ai5])/
06(Enable:[Ai6])/
09(Enable:[PA-25])
00
PA-25
DC voltage monitor
optional output value
0.0
~
300.0(%)
0.0
PA-26
Output
voltage monitor
optional output
enable
00(Disable)/
01(Enable:[Ai1])/
02(Enable:[Ai2])/
03(Enable:[Ai3])/
04(Enable:[Ai4])/
05(Enable:[Ai5])/
06(Enable:[Ai6])/
09(Enable:[PA-27])
00
PA-27
Output
voltage monitor
optional output value
setting
0.0
~
300.0(%)
0.0
PA-28
Output
torque monitor
optional output
enable
00(Disable)/
01(Enable:[Ai1])/
02(Enable:[Ai2])/
03(Enable:[Ai3])/
04(Enable:[Ai4])/
05(Enable:[Ai5])/
06(Enable:[Ai6])/
09(Enable:[PA-29])
00
PA-29
Output
torque monitor
optional output value
setting
0.0
~
300.0(%)
0.0
PA-30
Start with frequency
matching optional setting
enable
00(Disable)/
01(Enable: from Keypad)
02(Enable: from [Ai1])/
03(Enable: from [Ai2])/
04(Enable: from [Ai3])
01
PA-31
Start with frequency
matching optional value
setting
-500.0
~
500.0(%)
0.0
・
These are the simulation function settings.
For more information, refer to the user’s guide.
Содержание P1-00041HFEF
Страница 6: ...0 5 Contents Contents Memo ...
Страница 42: ...2 26 Chapter 2 Installation and Wiring Memo ...
Страница 129: ...Index Index 3 memo ...
Страница 130: ...Index Index 4 memo ...