3.2 Connecting the Power Cord
33
3
Chapte
r 3 Setting Prep
arations
1.
Confirm that the main power switch on the front panel of the main instrument and the circuit breaker
are turned off.
2.
Connect the supplied power cord of the equipment under test to the [LINE IN] line power terminal
block for equipment under test on the rear panel of the instrument.
3.
Connect the plug of the power cord to the isolation transformer.
4.
Connect the isolation transformer plug to a power supply with the voltage specified by the equip-
ment under test.
Connecting the power cord of the equipment under test
Preparation items : Power cord for equipment under test
Isolation transformer (separately purchased)
Isolation
transformer
[LINE IN]
[AC IN]
3
4
Use the screws
to secure
the connection
L
N
E
L
N
E
2
Secondary side of the
Isolation transformer
• When the power on polarity switching function is used, be sure not to
connect the neutral wire on the secondary side of the isolation trans-
former to ground. If it is connected to ground, a ground fault will occur.
• Use a voltmeter or voltage detector to make sure that terminal E [LINE IN]
is at ground potential (approx. 0 V). Failure to make this confirmation
could lead to electric shock or damage the instrument or the equipment
under test.
• When connecting the power cord of the equipment under test to the
[LINE IN] terminal, use a cord suitable for the capacity of the equipment
under test. Using a power cord with another rating may result in fire.
Содержание ST5540
Страница 2: ......
Страница 6: ...Contents iv Index i ...
Страница 29: ...23 2 Chapter 2 Instrument Labels and Screens Instrument Labels and Screens Chapter 2 ...
Страница 80: ...4 8 Changing the Measurement Method Auto Manual 74 ...
Страница 121: ...115 8 9 7 Chapter 7 Instrument System Settings Instrument System Settings Chapter 7 ...
Страница 144: ...7 14 Setting the Backlight 138 ...
Страница 284: ...10 14 Measurement Networks 278 ...
Страница 290: ...11 4 Instrument Disposal 284 ...
Страница 320: ...Appendix4 External Dimensions A30 ...
Страница 323: ......
Страница 324: ......
Страница 325: ......
Страница 326: ......